FC - Quality tested
Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤0.25 ?g per million cells in 100 ?l volume. It is recommended that the reagent be titrated for optimal performance for each application.
Flow Cytometry3,4: For most successful immunofluorescent staining results, it may be important to maximize signal over background by using a relatively bright fluorochrome-antibody conjugate (Cat. No. 113003/113004)or by using a high sensitivity, three-layer staining technique (e.g., including a biotinylated anti-hamster IgG second step (Cat. No. 405501), followed by SAv-PE (Cat. No. 405204)).
ELISA Capture2: The 55R-286 antibody is useful as a capture antibody when paired with the biotinylated 55R-170 antibody (Cat. No. 112904) as the detecting antibody.
Additional reported applications (for the relevant formats) include: Western blotting and immunoprecipitation1.
1. Aggarwal BB, et al. 1985. Nature 318 665.
2. Chan FKM, et al. 2000. Science 288:2351.
3. Loetscher H, et al. 1990. Cell 61:351.
4. Rothe J, et al. 1993. Nature 364:798.